- Country: USA
- Summary: Fire Suppression Service, Testing, Maintenance, Certification Amendment 2
- UST Ref No: 124713287
- Deadline: 20 Aug 2025
- Competition: ICB
- Financier: Self Financed
- Purchaser Ownership: Public
- Tender Value: Refer Document
- Notice Type: Tender
- Document Ref. No.: 36C25625Q1231
- Purchaser's Detail :
Purchaser : VETERANS AFFAIRS, DEPARTMENT OF
715 SOUTH PEAR ORCHARD RD., PLAZA 1, RIDGELAND , MS 39157, USA
Primary Point of Contact: Eugene Jackson, eugene.jackson2@va.gov, Phone Number (832) 352-2915
Email :eugene.jackson2@va.gov
- Description :
- Description
RFQ 36C25625Q1231 Question and Answer ReponsesThe purpose of this amendment is to: To reply to all questions that were submitted by the deadline of 08/15/2025 at 3pm CST. Extend the close date of the solicitation to 08-20-2025 at 16:30.Vendor 1Can you please provide copies of the most recent annual inspection reports for these systems?Answer: Yes, they can be supplied. Canteen/NFS semi-annual fire suppression testing was performed 3/19/2025.Which contract years will the future buildings be completed construction and devices added to this scope of work? Can you please share the fire sprinkler drawings for these buildings so we can get an idea of the added devices?Will inspections of the new above ground and underground water tanks be required under this contract? If so, please provide the drawings for these tanks.Answer: New Energy Plant- September 2025. New OI&T unknown, still in design stage.New building as-builts have not been provided, still under construction and have not been delivered as yet under contract. Above Ground water tank is not designated as fire protection. Both current underground tanks will become fire suppression dedicated.  Yes, that is the 1946 as built.When are each of the 5-year certification and testing required? Or when were they last performed? If unknown, will it be acceptable to include pricing in the base year and then move the funding to other years if it becomes known when these inspections will be required?Answer: 5 Year Certification and Testing: last performed in 2020, except for dry standpipe (2024) and gauges (2025)Internal Standpipe flow test (Bldg. 1)-base yearDiesel Fire Pump Flow test-base yearFire Hydrant flow GPM test-base yearFire Department Connection (FDC) Hydrostatic test-base yearFire Sprinkler Internal Piping Condition and Obstruction Inspection-base yearReplace all fire system gauges, to include negative gauge located on Fire Pump intake impeller-OY-5Dry Standpipe in Garage- OY-4The scope of work re...
- Documents :
Tender Notice
Att-4.pdf
Att-3.pdf
Att-2-Water-Storage-Reservoir.pdf
Att-1-Antifreeze.pdf
SF-30-Amendment-2.pdf
36C25625Q1231-0002_1.docx
SF-30-Amendment.pdf
36C25625Q1231-0001.docx
36C25625Q1231_1.docx
If you are registered member, kindly login to view full details of this tender notice:
CLICK HERE TO LOGIN