Methane Analyzer

USARFP notice for Methane Analyzer. The reference ID of the tender is 99575899 and it is closing on 05 Apr 2024.

100% Secure Payments

Tender Details

  • Country: USA
  • Summary: Methane Analyzer
  • UST Ref No: 99575899
  • Deadline: 05 Apr 2024
  • Competition: ICB
  • Financier: Self Financed
  • Purchaser Ownership: Public
  • Tender Value: Refer Document
  • Notice Type: Tender
  • Document Ref. No.: 1124832
  • Purchaser's Detail :
  • Purchaser : AGRICULTURE, DEPARTMENT OF
    Contracting Office Address : STONEVILLE , MS 38776
    Primary Point of Contact : Cecilia McNamee
    cecilia.mcnamee@usda.gov
    Phone Number 9852328289

    Email :cecilia.mcnamee@usda.gov

  • Description :
  • Description
    The USDA ARS location at 504 University Loop Jonesboro, AR 72401 UNITED STATES is looking for a Methane Analyzer, specifically Licor LI-7700 that meets the below specifications.

    A Li-Cor authorized distributor is required. This requirement will ensure that devices are not counterfeit or adulterated devices, have maintained adequate storage conditions, and any warranties and service and/or preventative maintenance agreements are transferred and will be honored by Li-Cor Biosciences


    Statement of work
    The LI-7700 analyzer is part of a system solely manufactured by LI-COR Biosciences. This sensor will measure methane production from an on-farm surface water reservoir used in agricultural production. The LI-7700 will be added to the existing data collection network infrastructure managed by the Delta Water Management Research Unit.
    The LI-7700 Open Path CH₄ Analyzer makes in-situ measurements of methane density with the resolution, speed, and stability required for the eddy covariance technique. The light weight, low power design provides the instrument the ability to acquire methane density data necessary to characterize ecosystem methane flux in remote environments. The open path design eliminates the need for pumps and tubing, and does not have pressure drops, tubing attenuation, or time delays associated with other closed path systems.
    Standard Features:

    Resolution (RMS noise): 5 ppb @ 10 Hz and 2000 ppb CH4 Measurement Range: 0 to 25 ppm @ -25 °C, 0 to 40 ppm @ 25 °C Data Communication: Ethernet (up to 40 Hz) Detection Method: Wavelength Modulation Spectroscopy 2f detection Linearity: Within 1% of reading Operating Pressure Range: 50 to 110 kPa Output Bandwidth: up to 20 Hz Operating Temperature Range: -25 to 50 °C Power Requirements: 10.5 to 30 VDC Power Consumption: 8 W nominal, 16 W during cleaning cycle Dimensions: Sensor: 14.33 cm dia (5.64 inches), 82.8 cm height (32.6 inches) Optical Path: 0.5 m phy...
  • Documents :
  •  Tender Notice

If you are registered member, kindly login to view full details of this tender notice:

CLICK HERE TO LOGIN
USARFP Features

USARFP Features

Fresh and verified Tenders from USA. Find, search and filter Tenders/Call for bids/RFIs/RFPs/RFQs/Auctions published by the government, public sector undertakings (PSUs) and private entities.

  • 1,000+ Tenders
  • Verified Tenders Only
  • Accurate Tender Information
  • New Tenders Every Day
  • Consultants for RFI/RFP/RFQ
  • Search, sort, and filter Tenders
  • Customer Support
  • Publish your Tenders
  • Consulting Services
  • Export data to Excel or CRM

Get A Call From Tender Experts

Fill out the form below and you will receive a call from us within 24 hours.

Thank You for Contacting ZimbabweTenders !!
Email Id is already exist !!
Invalid Captcha !

Get FREE SAMPLE TENDERS from USA in your email inbox.