- Description :
- Description
1. Introduction
This is a solicitation to provide the Robert J Dole VA Medical Center-s SPS department with a new Prevac Steam Sterilizer.
2. Scope of Work
The contractor shall deliver and perform certified installation and de-installation of the steam sterilizer. The contractor will provide all necessary materials, hardware, and attachments to ensure the steam sterilizer is fully functional and operational for use.
3. Technical Requirements
Item #
Description
QTY
Unit
1
AMSCO 400 26x37.5x48 Prevacuum Single Hinge Recessed, 1-Wall Lh Steam 20/V/240V - MFR# SR2222211011
1
EA
2
Deinstallation - Medium Sterilizers - MFR# SE6018521
1
EA
3
Install - Medium Sterilizer - MFR# SE601852
1
EA
4
Trade in STERIS Sterilizer
1
EA
Salient Features Stainless Steel Manual Single Hinge Door Recessed Interior Dimensions: 26 x 37.5 x 48” (660 x 950 x 1220mm) Overall Size: 44” x 70” x 75.25” Electrical: 120V, 2A, 1-Phase Vacuum Pump: 208/240V, 6A, 3-Phase, or; 480V, 3A, 3-Phase Touch-Sensitive Screen Thermal Printer 12 Programmable Cycles Customizable Cycle Options Process up to 15, 25lb Trays Technical Requirements Compatibility with Censis ConnectAssure. This program is required for sterilizer documentation. Inability to document sterilizer cycles for instrumentation if not compatible. Ability to fit in current footprint to include plumbing connections, electrical connections, and physical layout of room. Ability to change or adjust sterilization cycles and values at point-of-use to meet instrument manufacturer instructions for use, beyond sterilizer manufacturer pre-set cycles. Compatibility with 3M Comply SteriGage Steam Chemical Integrator (Class 5 Chemical Indicator) Compatibility with 3M Attest Super Rapid Readout Biological Indicator System