- Description :
- Description
Description of Work - Summary:
The switchgear in Building #1 at the Durham VA Health Care Center, 508 Fulton St, Durham, NC has been inspected and deemed deficient. There is an immediate need to replace the switchgear as it is past its life cycle.
Estimated construction magnitude is between $2,000,000 and $5,000,000.
NAICS CODE: 236220 Size Standard: $45.0 Million
General:
The contractor shall upgrade the distribution system for building 18 normal power switchgear and transformers to meet the power requirement for redundancy in Building 18 at the Durham VA Health Care System. The contractor shall provide phasing coordination for each section below to minimize impact to normal operations. The contractor is responsible for providing all supervision, materials, labor, equipment, transportation, testing, and storage for this project. The contractor may be required to provide alternate source of power to minimize operation impacts. The contractor shall replace the existing substation B18-SWGR-Main A/B including transformers B18-XF-T6 and B18-XF. All work shall be performed according to the attached drawings and specifications.
Specific Requirements:
The construction for this project will cover the following but not limited to:
Provide new switchgear and related transformers in Building1 BG-000 Provide new Substations and distribution switchgear. Provide new transformers to replace T-6 and T-7. Provide a new tie breaker that can properly transfer power without having manually load shed power to close the breaker. Relocate the distribution circuits to the new switchgear room. Provide a concrete foundation to house the new switchgear. Modify the existing OIT and HAC closet. Modify the existing location to properly house the new equipment. Provide a warranty in accordance with the FAR.All material and installation will be in accordance to all state and federal codes, NFPA, ANSI standards, drawings, and specifications. Electri...
- Documents :
Tender Notice
36C24625B0026-0004.docx
36C24625B0026-0003.docx
36C24625B0026-0002.docx
Pre-Bid-site-Visit-Replace-Switchgear.pdf
36C24625B0026-0001.docx
S02-36C24625B0026_1-Solicitation-06162025.pdf
9_SwitchGear-Drawings-Bid-20250220.pdf
9_Bid-Specs-20250220.docx
9_Asbestos-2018-9-13-18-bldg-1-drawings.pdf